Description
Conductor material bare copper strand Conductor class acc. to IEC 60228 cl. 5; exception: 0,34 mm², stranded (7 x 0,25 mm)
Core insulation PVC Core identification acc. to DIN 47100 different colours Stranding stranded in layers Overall shield copper braid tinned, coverage approx. 85%
Outer sheath material PVC Sheath colour grey, RAL 7001; LIYCY single core: grey RAL 7001
Rated voltage AC IEC Uo/U: 250 V; peak-voltage on 0,14 mm² 350 V; > 0,14 mm² 500 V
Testing voltage on 0,14 mm² core/core: 1,2 kV; core/shield: 1,0 kV > 0,14 mm²: core/core: 1,5 kV; core/shield: 1,0 kV
Conductor resistance acc.to IEC 60228 cl. 5 Insulation resistance min. 20 MΩ x km
Current carrying capacity acc. to DIN VDE, see Technical Guidelines
Capacity core/core ca. 120 nF/km; core/shield ca. 160 nF/km
Min. bending radius fixed up to 12 mm Ø 5 x d; up to 20 mm Ø 7,5 x d; > 20 mm Ø 10 x d Min.
bending radius moved up to 12 mm Ø 10 x d; up to 20 mm Ø 15 x d; > 20 mm Ø 20 x d
Operat. temp. fixed min./max. [°C] -30 °C / +80 °C
Operat. temp. moved min/max [°C] -5 °C / +70 °C